    Description

    Briggs and Stratton Power System Management System #71042
    Manufactured by Briggs and Stratton for GE
    Will have GE logo on the panel.
    Pictures are of the item.
    Equipment Description:
    This system is designed to control four priority loads and up to two air conditioner loads that are being supplied by power generated by the home dtandby system.
    This system goes into a standby mode and does not control any loads when utility power is present.
    The power management system consists of four 50 amp, 2 HP, 2 pole relays; four control relays for centeral air conditioning control wiring (maximum 1 amp, 30VAC,
    two of these relays are air conditioning lock out). The circuit boards are house in a NEMA 3R enclosure that is suitable for indoor or outdoor use.
    Relays A1 and A2 are configured with a 5 minute delay for use with air conditioning control wiring. The 5 minute delay will aloow air conditioner head pressure to bleed off,
    thus reducing in-rush current. Please contact the air condeitioning manufacturer to make sure their unit incorporates and 5 minute starting delay.
    Two current transformers monitor generator current at the transfer switch to ensure the generator load does not exceed the pre detemined level.
    Should load exceed the predetermined level, the system will shed loads to prevent the generator from overloading.
    Loads are added sequentialy when sufficient power becomes available.
    The load control module incorporates a LED for each Relay. The LOAD1 LED is lit when relay 1 is NOT supplying power to the load.( Contactor is open)
    The same is true for the other three relay's. There is also a STATUS LED on the control module that flashes wheb the generator is supplying power to the system and
    indicates that the esuipment is functioning properly.
    Only a licensed  electrician should install this item.
    Product specifications:
    Rated AC Voltage 240 Volts
    Frequency  60hz
    Contactor Rating   L1,L2,L3,L4     240 VAC 50A, 2 HP
    Relay Contacts Rating A1,A2,A3,A4  30 VAC, 1A, CLASS 2
    DIMENSIONS
    Height 24
    Width 14
    Deep 6.5
    Weight 45 lbs.